Model Designations
1. Safety ball valve
2. L: Straight through threaded connection
LS: Right angle~~
LW: Three-way~~
3. Nominal diameter: 20, 25, 32, 40mm
4. Nominal pressure:
H1--10MPa
H2--20MPa
H3--31.5MPa
5. Type of structure: Straight through

AQF Safety Ball Valves are mainly used in hydraulic bladder accumulators as safety, flow interruption, and unloading accessories. The safety valve maintains the system's set pressure value. When the pressure exceeds the set value, the safety valve opens to prevent system overload. It is especially essential for accumulators in closed systems, effectively preventing damage caused by sudden increases in external load.
Its core function is to protect the accumulator and the entire hydraulic circuit by controlling the flow of hydraulic fluid to prevent system overload and unload.
Features: Compact structure, small size, safe and convenient, simple operation.

Main Functions and Working Principle
1. Pressure Setting and Relief: The valve has an internal spring or pilot valve structure. When the hydraulic system pressure exceeds the user-set safety value (e.g., 31.5MPa), the valve automatically opens, quickly releasing hydraulic fluid to prevent further pressure rise that could lead to accumulator explosion or pipeline rupture.
2. Safety Flow Interruption: Acts as a "gate" between the accumulator and the system. In the event of a sudden high-load impact in the system, the safety valve can quickly cut off the oil circuit, protecting the equipment from damage.
3. Unloading and Oil Drainage: In addition to its protective function, it is also commonly used as an oil drain valve to quickly drain the oil from the accumulator for maintenance or replacement.
We can design and develop according to the needs of our customers to meet the requirements of different clients.
Model Designations
1. Safety ball valve
2. L: Straight through threaded connection
LS: Right angle~~
LW: Three-way~~
3. Nominal diameter: 20, 25, 32, 40mm
4. Nominal pressure:
H1--10MPa
H2--20MPa
H3--31.5MPa
5. Type of structure: Straight through
Overall Dimension
| Model | Nominal flow (Safety valve) (L/min) | Nominal flow (Ball valve) (L/min) | Connection size d (mm) | Connection size d1 (mm) | Matching accumulator (L) |
| AQF-L25H※-A | 40 | 100 | M42×2 or M27×2 | M33×2 | 1.6~10 |
| AQF-LS25H※-A | 40 | 100 | M42×2 or M27×2 | M33×2 | 1.6~10 |
| AQF-LW25H※-A | 40 | 100 | M42×2 or M27×2 | M33×2 | 1.6~10 |
| AQF-L32H※-A | 63 | 160 | M60×2 or M42×2 | M42×2 | 10~100 |
| AQF-LS32H※-A | 63 | 160 | M60×2 or M42×2 | M42×2 | 10~100 |
| AQF-LW32H※-A | 63 | 160 | M60×2 or M42×2 | M42×2 | 10~100 |
| AQF-L40H※-A | 100 | 250 | M72×2 or M60×2 | M48×2 | 10~100 |
| AQF-LS40H※-A | 100 | 250 | M72×2 or M60×2 | M48×2 | 10~100 |
| AQF-LW40H※-A | 100 | 250 | M72×2 or M60×2 | M48×2 | 10~100 |
A 1.5 L threaded diaphragm accumulator screwed straight into a manifold block is one of the tidiest ways to hold clamping pressure on a machine tool. Charge it to 60 bar on a 20 °C bench, ship the same unit to...
READ MOREA 0.32 L diaphragm accumulator leaves the factory charged to 60 bar. Six months later, on a machine whose oil runs at 45 °C, that same unit may read close to 68 bar, and the engineer who never re-checked the p...
READ MOREA 315 bar clamping circuit on a die-casting machine has to hold force for about two seconds after the pump stops. A one litre diaphragm accumulator covers that duty with a precharge that stays within a few per...
READ MOREPicture a 3 MW turbine on a cold February night. The hydraulic power unit trips, the pump stops, and the pitch system has seconds to feather three blades. The only energy left is the nitrogen precharge sitting...
READ MORE