Model Designations
1. Safety ball valve
2. L: Straight through threaded connection
LS: Right angle~~
LW: Three-way~~
3. Nominal diameter: 20, 25, 32, 40mm
4. Nominal pressure:
H1--10MPa
H2--20MPa
H3--31.5MPa
5. Type of structure: Straight through

AQF Safety Ball Valves are mainly used in hydraulic bladder accumulators as safety, flow interruption, and unloading accessories. The safety valve maintains the system's set pressure value. When the pressure exceeds the set value, the safety valve opens to prevent system overload. It is especially essential for accumulators in closed systems, effectively preventing damage caused by sudden increases in external load.
Its core function is to protect the accumulator and the entire hydraulic circuit by controlling the flow of hydraulic fluid to prevent system overload and unload.
Features: Compact structure, small size, safe and convenient, simple operation.

Main Functions and Working Principle
1. Pressure Setting and Relief: The valve has an internal spring or pilot valve structure. When the hydraulic system pressure exceeds the user-set safety value (e.g., 31.5MPa), the valve automatically opens, quickly releasing hydraulic fluid to prevent further pressure rise that could lead to accumulator explosion or pipeline rupture.
2. Safety Flow Interruption: Acts as a "gate" between the accumulator and the system. In the event of a sudden high-load impact in the system, the safety valve can quickly cut off the oil circuit, protecting the equipment from damage.
3. Unloading and Oil Drainage: In addition to its protective function, it is also commonly used as an oil drain valve to quickly drain the oil from the accumulator for maintenance or replacement.
We can design and develop according to the needs of our customers to meet the requirements of different clients.
Model Designations
1. Safety ball valve
2. L: Straight through threaded connection
LS: Right angle~~
LW: Three-way~~
3. Nominal diameter: 20, 25, 32, 40mm
4. Nominal pressure:
H1--10MPa
H2--20MPa
H3--31.5MPa
5. Type of structure: Straight through
Overall Dimension
| Model | Nominal flow (Safety valve) (L/min) | Nominal flow (Ball valve) (L/min) | Connection size d (mm) | Connection size d1 (mm) | Matching accumulator (L) |
| AQF-L25H※-A | 40 | 100 | M42×2 or M27×2 | M33×2 | 1.6~10 |
| AQF-LS25H※-A | 40 | 100 | M42×2 or M27×2 | M33×2 | 1.6~10 |
| AQF-LW25H※-A | 40 | 100 | M42×2 or M27×2 | M33×2 | 1.6~10 |
| AQF-L32H※-A | 63 | 160 | M60×2 or M42×2 | M42×2 | 10~100 |
| AQF-LS32H※-A | 63 | 160 | M60×2 or M42×2 | M42×2 | 10~100 |
| AQF-LW32H※-A | 63 | 160 | M60×2 or M42×2 | M42×2 | 10~100 |
| AQF-L40H※-A | 100 | 250 | M72×2 or M60×2 | M48×2 | 10~100 |
| AQF-LS40H※-A | 100 | 250 | M72×2 or M60×2 | M48×2 | 10~100 |
| AQF-LW40H※-A | 100 | 250 | M72×2 or M60×2 | M48×2 | 10~100 |
What Is an Accumulator Charging Kit and What Does It Do? An accumulator charging kit is a specialized set of tools used to safely charge, check, and adjust the nitrogen gas pre-charge pressure inside hydraulic...
READ MOREHow to Choose the Right Hydraulic Valve: The Direct Answer Choosing the right hydraulic valve for an application comes down to five core parameters: valve function (directional, pressure, or flow control), sys...
READ MOREAn accumulator is a pressure storage device used in hydraulic systems to store energy in the form of pressurized fluid and release it on demand. It works by separating a pre-charged nitrogen gas from hydraulic...
READ MOREPiston accumulators separate gas and fluid with metal pistons. They feature strong pressure resistance and a wide range of volume options, enabling high-pressure energy storage and long-term pressure maintenanc...
READ MORE